Date: 2016/05/14 Observers: Kara Ponder, Daniel Perrefort OA: Doug Williams Number Observation Int Time Filter Airmass Seeing Notes 1-11 dark 5 4:07 OPAQ - - - 12-22 flat 5 4:36 J - - lamps on at 600, low counts. 7000 instead of 11000. a lamp was misaligned 23-33 flat 5 4:45 J - - lamps on at 600, 11000 counts 34-44 flat 5 4:51 H - - lamps on at 425 45-55 flat 5 4:56 Ks - - lamps on at 380 56-66 flat 5 5:00 Ks - - lamps off 67-77 flat 5 5:05 H - - lamps off 78-88 flat 5 5:10 J - - lamps off Domes closed due to threatenting clouds. Trying something at 11:15 pm. 89-90 P212-C 5/10 11:15 H 1.59 - acquire, clouds blocking everything 91-98 P330-E 5 11:20 H 1.13 - acquire. there's something there!, having issues getting contours with imexam. 99-107 P330-E 10 11:30 H 1.1 1-1.3 3x3x30" 108-116 P330-E 10 11:34 J 1.09 1+ 3x3x30" 117-125 P330-E 10 11:39 Ks 1.08 1+ 3x3x30", this filter gave contours 126 SN2013be 10 11:45 H 1.25 - acquire, nothing there/unsure where we are. Bad direction trying a target in the East 127 ASASSN-15fs 5 12:10 Ks 1.4 - acquire 128 ASASSN-15fs 5 - J - - acquire, checking position 129-154 ASASSN-15fs 60 12:15 Ks 1.38 1.3-1.5 5x5x15", lost guiding around 134. imexam for contours not working. unsure of focus End at 12:49 am. Note: Next day, played with parameters more, increasing the number of contours seemed to fix the problem.